 40A DC UPS Module
Features :
DR-UPS40
Battery controller for DIN Rail UPS system Parallel connection to DC BUS Suitable for 24V system up to 40A Installed on DIN Rail TS35 / 7.5 or 15 Built-in battery test function Battery polarity protection Relay contact signal output and LED indicator for DC BUS OK, Battery Fail, and Battery Discharge Cooling by free air convection 3 years warranty
SPECIFICATION
MODEL DC INPUT / DC VOLTAGE (Typ.) DC BUS RATED CURRENT BATTERY INPUT / OUTPUT VOLTAGE RANGE (Typ.) CURRENT RANGE CHARGE CURRENT (Typ.) EXTERNAL BATTERY (Typ.) DR-UPS40 24 ~ 29V 40A 21 ~ 29V 0 ~ 40A 2A 4 / 7 / 12AH / 24V Relay contact : Short when DC voltage between 21~29V( 3%), relay contacts LED(Green) : DC BUS OK : light ; DC BUS fail : dark
Note.2
RELAY CONTACT RATING (max.) 30VDC, 1A DC BUS OK FUNCTION BATTERY FAIL BATTERY DISCHARGE WORKING TEMP. ENVIRONMENT WORKING HUMIDITY VIBRATION
Relay contact : Short when battery failure is observed through the battery test function, relay contacts LED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : dark Relay contact : Short when battery in discharge condition, relay contacts LED(Yellow) : Battery discharging : light ; Battery is not discharging or discharging current<2.0A : dark -20 ~ +70 20 ~ 90% RH , 10 ~ 95% RH Component : 10 ~ 500Hz, 2G 10min./1cycle, 60min. each X, Y, Z axes ; Mounting : Compliance to IEC600068-2-6
STORAGE TEMP., HUMIDITY -20 ~ +85
Terminal-Chassis :0.5KVAC, Relay Contacts-Terminal :0.5KVAC WITHSTAND VOLTAGE Terminal-Chassis :>100M Ohms/500VDC 25 70%RH SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8, ENV50204, heavy industry level, criteria A 161.9Khrs min. MIL-HDBK-217F (25 ) 55.5*125.2*100mm (W*H*D) 0.55Kg; 20pcs/12Kg/1.29CUFT
1. All parameters NOT specially mentioned are measured at rated load and 25 of ambient temperature. 2. Every 25 seconds, unit will send out test signal through "Battery Fail" relay contact and LED indicator once the battery is fail.
File Name:DR-UPS40-SPEC 2007-09-19
40A DC UPS Module
Mechanical Specification
DR-UPS40
Case No.923D Unit:mm
125.2
LED TB1 TB2
1 2 3 4 5 6
1 2 3 4
100
Terminal Pin No. Assignment (TB1)
Pin No. 1 2 3 4 Assignment BATTERY INPUT + BATTERY INPUT DC INPUT DC INPUT +
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
Terminal Pin No. Assignment (TB2)
Pin No. 1 2 3 4 5 6 Assignment BAT DISC 1 BAT DISC 2 BAT FAIL 1 BAT FAIL 2 DC OK 1 DC OK 2
Block Diagram
Derating Curve
LOAD +
25Ax2 + CHARGE CIRCUIT LIMIT BAT. TEST
100
24V BATTERY
80
INPUT POWER SUPPLY
60
LOAD (%)
40
DETECTION CIRCUIT
20
-20
DC OK BAT BAT FAIL DISCHARGE
0
10
20
30
45
50
60
70 (VERTICAL)
AMBIENT TEMPERATURE ( )
File Name:DR-UPS40-SPEC 2007-09-19
55.5
35
40A DC UPS Module
Suggested Application
1.Back up connection for AC interruption
DR-UPS40
DR-UPS40
24V Battery BAT +DC -+
PSU 24V/40A max. Load
+
+
-
+
-
2.Combine redundancy module (DR-RDN20) to back up AC interruption or failure of PSU
DR-UPS40
DR-RDN20
24V Battery BAT DC +--+ Vout Vin
PSU
Load
+ - - - B+ A+ + +
-
+
-
File Name:DR-UPS40-SPEC 2007-09-19


▲Up To Search▲   

 
Price & Availability of DR-UPS40

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X